Silicone Polymer Line Post Insulator
- Weathersheds:
- These Insulators are manufactured with silicone rubber with proprietary compound, the same proven material used in transmission insulators.
Insulators are available with other ANSI and IEC end fittings. Please refer to the catalog for the configurable options available.
One example of many models
General
Application | Horizontal Line Post |
Cantilever Bending Strength – Max. | 2470 Lbs (11.0 kN) |
Cantilever Bending Strength – Routine | 1235 Lbs. (5.5 kN) |
Fitting – Ground/Base | 3/4″ Stud Base |
Fitting – Live Line End | Horizontal Clamptop |
Material | Silicone |
Material – End Fitting | Galvanized Steel |
Number of Sheds | 12 |
Tension Range | 2500 lb |
UPC | 096359438779 |
Dimensions
Angle | 0 |
Diameter – Shed(s) | 7.5″ (190mm) / 5.2″ (132mm) |
Length – Effective | 26.46 in |
Rod Diameter | 1.75 in |
Thickness – Housing | 0.15″ (3.8mm) |
Weight | 15.9 lb |
Electrical Ratings
Arc Distance – Dry | 22.3″ (566mm) |
Creep and Leakage Distance | 58.2″ (1478mm) |
Critical Impulse Flashover (CIFO) – Positive | 360 kV |
Flashover Voltage – 60 Hz Dry | 230 kV |
Flashover Voltage – 60 Hz Wet | 180 kV |
Voltage – Line | 69000 V |
Voltage Rating | 69 kV |
Withstand Voltage – Lightning Impulse (Positive) | 330 kV |
Certifications and Compliance
Industry Standard(s) | ANSI |
Logistics
Pallet Quantity | 35 EA |
A silicone polymer line post insulator mainly consists of a core rod (ECR type or FRP type), a silicone rubber housing and metal end connections. Usually, polymer line post insulators are mounted on a supporting structure such as a wood / steel mast or a tower by means of an additional base. WINNING® supplies line post insulators with FOUR core sizes for distribution line applications from 15 kV to 69 kV and FIVE form sizes for transmission line applications with different voltage levels from 69 kV to 500 kV.
Core – Made from high quality pultruded epoxy rod (ECR type).
End pieces – Ductile iron after hot-dip galvanizing according to IEC & ASTM standard.
Base – It is mainly a rigidly curved base, a flexible curved base (also known as a reinforcement base) and a flat base (steel channel), a flange base and a bolt base (for insulators under 69 kV).
Silicone rubber housing – HTV silicone rubber made from high quality raw materials.
Corona Ring – Made of high quality aluminum alloy.
Sealing – The connection between the end piece and the core rod is completely embedded in HTV silicone rubber, which avoids conventional and conventional sealing errors. (The other type is available, which uses RTV silicone sealant to seal the joint between the end piece and core rod.)
Pin Type Line Post Insulators: Simple Tie Top, F Neck Cap Type; 15kV to 35kV distribution line.
Vertical Line Post Insulators: Vertical Top Clamp, K Clamp;
Horizontal line post insulators: horizontal upper clamp, two-hole blade (drop tongue)
Brace Line Post Insulator: Combination of Silicone Polymer Long Rod Suspension Insulator and Silicone Polymer Horizontal Line Post Insulator.